info@cbibreakers.com  🗲  35 E Uwchlan Ave Exton PA 19341  🗲  +1 610 524 9949

DIN Rail (35mm) or Surface

DIN Rail (35mm) or Surface

A DIN rail is a metal rail (35mm) used for mounting inside equipment racks. The rail is known as the TS35 rail in the USA. DIN Rail products can also be used for surface mounting.

D1G2LX2RAS1100LBBXXXXXWAVAB1X

D1G2LX2RAS1100LBBXXXXXWAVAB1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 11A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D1GLB20002

D1G2LX3RAS0250LBBXXXXXWAVAB1X

D1G2LX3RAS0250LBBXXXXXWAVAB1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 2.5A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D1GLB20001

D2G2LX2RAS1100LBBXXXXXWAVAB1X

D2G2LX2RAS1100LBBXXXXXWAVAB1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 11A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GLB20004

D2G2LX2RAS3000LBBXXXXXWAVAB1X

D2G2LX2RAS3000LBBXXXXXWAVAB1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GLB20002

D2G2LX3RAS0250LBBXXXXXWAVAB1X

D2G2LX3RAS0250LBBXXXXXWAVAB1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 2.5A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GLB20005

D2G2LX3RAS1300LBBXXXXXWAVAZ1X

D2G2LX3RAS1300LBBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 13A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GLA20001

D2GALX2RAS0800KXBXXXXXWAVAZ1X

D2GALX2RAS0800KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 8A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GBXA0039

D2GALX3QAS0250KXBXXXXXWAVAZ1X

D2GALX3QAS0250KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 2.5A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GKXA0006

D2GALX3RAS0100KXBXXXXXWAVAZ1X

D2GALX3RAS0100KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 1A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GBXA0020

D2GALX3RAS0130KXBXXXXXWAVAZ1X

D2GALX3RAS0130KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 1.3A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GBXA0010

D2GALX3RAS0420KXBXXXXXWAVAZ1X

D2GALX3RAS0420KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 4.2A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GBXA0022

D2GALX3RAS3500KXBXXXXXWAVAZ1X

D2GALX3RAS3500KXBXXXXXWAVAZ1X

  • Frame: DD-Frame
  • Mounting: Rail and Surface Mount
  • Handle Type: Standard Handle
  • Termination: Clamp Terminal 3,5mm - Top and Bottom
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Colour: White handle, Black marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Special Specify
  • Approvals: CUR, UL recognised UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable
D2GBXA0013

Become a distributor

If you are an electrical supplier, why not find out the benefits of becoming a CBI distributor!

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Protect your assets

Superior circuit breakers for equipment.